<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aquaria Srl &#187; CALIBRATION SYSTEM_FLOWMETER</title>
	<atom:link href="https://www.aquariasrl.com/en/category/calibration-system_flowmeter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.aquariasrl.com/en</link>
	<description>Instruments for environmental monitoring</description>
	<lastBuildDate>Mon, 26 May 2025 07:39:01 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.26</generator>
	<item>
		<title>FLOWMETER</title>
		<link>https://www.aquariasrl.com/en/flussimetri-a-sfera/</link>
		<comments>https://www.aquariasrl.com/en/flussimetri-a-sfera/#comments</comments>
		<pubDate>Thu, 19 Nov 2015 11:54:00 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[CALIBRATION SYSTEM_FLOWMETER]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=514</guid>
		<description><![CDATA[A constant and reliable control of the flow is the basis of an appropriate and correct sampling, an indispensable condition to obtain significant analytical results. A correct flow control line is composed by: air sampler (high and low flow) device to be used for sampling (filter holder, vial, impinger, etc.) calibrator The sampling device should be<p><a href="https://www.aquariasrl.com/en/flussimetri-a-sfera/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;">A constant and reliable control of the flow is the basis of an appropriate and correct sampling, an indispensable condition to obtain significant analytical results.</p>
<p style="text-align: justify;">A correct <span style="color: #2a7ebc;"><strong><em>flow control line </em></strong></span>is composed by:</p>
<ul style="text-align: justify;">
<li>air sampler (high and low flow)</li>
<li>device to be used for sampling (filter holder, vial, impinger, etc.)</li>
<li>calibrator</li>
</ul>
<p style="text-align: justify;">The sampling device should be placed between the pump and the flow meter for a more precise adjustment by simulating effective pressure drop.</p>
<p><span style="color: #2a7ebc;"><strong><em><br />FLOWMETER CERTIFIED &#8220;UKAS&#8221;</em></strong></span></p>
<p><em><strong>Models with borosilicate glass tube &#8211; height: 300 mm </strong></em><br /><em><strong>Accuracy ± 1.2% of measured value; ± 0.4% of full scale</strong></em></p>
<ul style="list-style-type: circle;">
<li style="text-align: justify;">Measure range: 0,2 – 2,5 l/min   (graduated scale every 0,1 l/min)</li>
<li style="text-align: justify;">Measure range: 0,5 – 5,0 l/min   (graduated scale every 0,1 l/min)</li>
<li style="text-align: justify;">Measure range: 1 – 10 l/min    (graduated scale every 0,2 l/min)</li>
<li style="text-align: justify;">Measure range: 1 – 15 l/min    (graduated scale every 0,2 l/min)</li>
<li style="text-align: justify;">Measure range: 2 – 25 l/min    (graduated scale every 0,5 l/min)</li>
</ul>
<p style="text-align: justify;"><strong><em><span style="color: #2a7ebc;"><br />FLOWMWTER NOT CERTIFIED</span> </em></strong></p>
<p><em><strong>Models with borosilicate glass tube &#8211; height: 300 mm </strong></em><br /><em><strong>Accuracy ± 1.2% of measured value; ± 0.4% of full scale</strong></em></p>
<ul style="list-style-type: circle;">
<li style="text-align: justify;">Measure range: 0,2 – 2,5 l/min   (graduated scale every 0,1 l/min)</li>
<li style="text-align: justify;">Measure range: 0,5 – 5,0 l/min   (graduated scale every0,1 l/min)</li>
<li style="text-align: justify;">Measure range:: 1 – 10 l/min    (graduated scale every 0,2 l/min)</li>
<li style="text-align: justify;">Measure range: 1 – 15 l/min    (graduated scale every 0,2 l/min)</li>
<li style="text-align: justify;">Measure range: 2 – 25 l/min    (graduated scale every 0,5 l/min)</li>
<li style="text-align: justify;">Measure range: 5 – 50 l/min    (graduated scale every 1 l/min)</li>
</ul>
<p style="text-align: justify;"> </p>
<p><em><strong>Models with borosilicate glass tube height: 100 mm</strong></em><br /><em><strong>Accuracy ± 1.25% of full scale</strong></em></p>
<ul style="list-style-type: circle;">
<li style="text-align: justify;">Measure range:0,2 – 2 l/min      (graduated scale every 0,1 l/min)</li>
<li style="text-align: justify;">Measure range: 0,2 – 3,4 l/min   (graduated scale every 0,2 l/min)</li>
<li style="text-align: justify;">Measure range: 0,6 – 5 l/min      (graduated scale every 0,2 l/min)</li>
<li style="text-align: justify;">Measure range: 1 – 10 l/min      (graduated scale every 0,5 l/min)</li>
<li style="text-align: justify;">Measure range:1 – 12 l/min    (graduated scale every 0,5 l/min)</li>
<li style="text-align: justify;">Measure range: 2 – 25 l/min    (graduated scale every 1 l/min)</li>
<li style="text-align: justify;">Measure range: 6 – 50 l/min    (graduated scale every 2 l/min)</li>
</ul>
<p style="text-align: justify;"> </p>
<p><em><strong>Models with borosilicate glass tube height: 150 mm </strong></em><br /><em><strong>Accuracy ± 3% of measured value</strong></em></p>
<ul style="list-style-type: circle;">
<li style="text-align: justify;">Measure range:   5 – 100 ml/min</li>
<li style="text-align: justify;">Measure range:  20 – 250 ml/min</li>
<li style="text-align: justify;">Measure range:  60 – 600 ml/min</li>
</ul>
<p style="text-align: justify;"><strong><br />N.B.: flowmeters are available with different ranges &#8211; please request specific price list</strong></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/flussimetri-a-sfera/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
