<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aquaria Srl</title>
	<atom:link href="https://www.aquariasrl.com/en/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.aquariasrl.com/en</link>
	<description>Instruments for environmental monitoring</description>
	<lastBuildDate>Mon, 26 May 2025 07:39:01 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.26</generator>
	<item>
		<title>LAMINAR AND CHEMICAL HOODS</title>
		<link>https://www.aquariasrl.com/en/2313/</link>
		<comments>https://www.aquariasrl.com/en/2313/#comments</comments>
		<pubDate>Mon, 26 May 2025 07:29:18 +0000</pubDate>
		<dc:creator><![CDATA[Gianmarco Tundo]]></dc:creator>
				<category><![CDATA[Senza categoria]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/en/?p=2313</guid>
		<description><![CDATA[01_FOLDER_CAPPE_ENG_24]]></description>
				<content:encoded><![CDATA[<p><a href="https://www.aquariasrl.com/en/wp-content/uploads/2025/05/01_FOLDER_CAPPE_ENG_24.pdf">01_FOLDER_CAPPE_ENG_24</a></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/2313/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Variazione codici campionatori passivi a simmetria radiale: RING SO2-NO2</title>
		<link>https://www.aquariasrl.com/en/variazione-codici-campionatori-passivi-a-simmetria-radiale-ring-so2-no2/</link>
		<comments>https://www.aquariasrl.com/en/variazione-codici-campionatori-passivi-a-simmetria-radiale-ring-so2-no2/#comments</comments>
		<pubDate>Fri, 09 Nov 2018 13:41:14 +0000</pubDate>
		<dc:creator><![CDATA[Gianmarco Tundo]]></dc:creator>
				<category><![CDATA[Senza categoria]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/en/?p=2267</guid>
		<description><![CDATA[  Per venire incontro alle esigenze della clientela e fornire uno strumento unico per il campionamento di Biossido di Zolfo (SO2) e Biossido di Azoto (NO2), sono stati rimossi i codici P.702R e P.704R (rispettivamente Ring per campionamento di SO2 e NO2) e sostituiti con l’unico codice P.711R (Ring per il campionamento di SO2/ NO2) che permette il campionamento di<p><a href="https://www.aquariasrl.com/en/variazione-codici-campionatori-passivi-a-simmetria-radiale-ring-so2-no2/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p style="text-align: center;"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2014/12/logo.png"><img class="alignnone size-full wp-image-26" src="http://www.aquariasrl.com/en/wp-content/uploads/2014/12/logo.png" alt="logo" width="110" height="100" /></a></p>
<p style="text-align: center;"> </p>
<p style="text-align: center;"><span style="color: #3366ff;">Per venire incontro alle esigenze della clientela e fornire uno strumento unico per il campionamento di Biossido di Zolfo (SO2) e Biossido di Azoto (NO2), sono stati rimossi i codici P.702R e P.704R (rispettivamente Ring per campionamento di SO2 e NO2) e <span style="font-size: 20px;"><strong><span style="color: #000000;"><span style="text-decoration: underline;">sostituiti</span> </span></strong></span>con l’unico codice P.711R (Ring per il campionamento di SO2/ NO2) che permette il campionamento di entrambi gli inquinanti con la stessa cartuccia adsorbente.</span></p>
<p style="text-align: center;"><span style="color: #3366ff;">In fase di analisi, l&#8217;estrazione dell&#8217;inquinante sarà unica ottenendo dunque informazioni o su biossido di zolfo o su biossido di azoto.</span></p>
<p style="text-align: center;"><span style="color: #3366ff;">Inoltre, si comunica che la nuova cartuccia adsorbente per i seguenti inquinanti: SO2/NO2 , HF , CO2 , NH3 e H2S è in materiale plastico con tappo di chiusura di colore blu.</span></p>
<p> <a href="http://www.aquariasrl.com/en/wp-content/uploads/2018/11/Copertura-e-tappo-cartuccia-RING.jpg"><img class="alignnone size-medium wp-image-2269 aligncenter" src="http://www.aquariasrl.com/en/wp-content/uploads/2018/11/Copertura-e-tappo-cartuccia-RING-300x225.jpg" alt="copertura-e-tappo-cartuccia-ring" width="300" height="225" /></a></p>
<p>&nbsp;</p>
<p><a href="http://www.aquariasrl.com/en/wp-content/uploads/2018/11/Biglietto_AQUARIA_1.png"><img class="alignnone size-medium wp-image-2271" src="http://www.aquariasrl.com/en/wp-content/uploads/2018/11/Biglietto_AQUARIA_1-300x100.png" alt="biglietto_aquaria_1" width="300" height="100" /></a></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/variazione-codici-campionatori-passivi-a-simmetria-radiale-ring-so2-no2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SMOKE TEST TUBE</title>
		<link>https://www.aquariasrl.com/en/smoke-test-tube/</link>
		<comments>https://www.aquariasrl.com/en/smoke-test-tube/#comments</comments>
		<pubDate>Fri, 21 Oct 2016 13:24:41 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Smoke tubes]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/en/?p=2235</guid>
		<description><![CDATA[Smoke test tubes contain a brown-orange material impregnated with smoke sulfuric acid. When air is pumped through the tube, with the help of a rubber blower, an aerosol of sulfuric acid in the form of white smoke comes out. The density of the smoke generated by sulfuric acid increases with increasing atmospheric humidity. The smoke would<p><a href="https://www.aquariasrl.com/en/smoke-test-tube/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p><em><strong><span style="color: #2a7ebc;">Smoke test tubes</span></strong></em> contain a brown-orange material impregnated with smoke sulfuric acid. When air is pumped through the tube, with the help of a rubber blower, an aerosol of sulfuric acid in the form of white smoke comes out. The density of the smoke generated by sulfuric acid increases with increasing atmospheric humidity. The smoke would not be visible, if it were generated in a completely moisture-free air.</p>
<p>The vials, once used, can be inerted with water and then disposed as special waste.<br />Tubes can be used within a temperature range between 0 and 40 ° C and a humidity from 3 to 50 mg/l (corresponding to 100% relative humidity at 40 °C).</p>
<p><em><strong><span style="color: #2a7ebc;">Reaction principle:</span></strong></em> H<sub>2</sub>S<sub>2</sub>O<sub>7</sub> + H<sub>2</sub>O = H<sub>2</sub>SO<sub>4</sub> aerosol </p>
<p><span id="more-2235"></span></p>
<p style="text-align: justify;"><em><strong><span style="color: #2a7ebc;"><br />FIELDS OF APPLICATION:</span></strong></em></p>
<ul style="list-style-type: square;">
<li>detection of the direction and intensity of air currents in ventilated rooms</li>
<li>control of the air flows in laminar flow hoods</li>
<li>monitoring of ventilation, air conditioning, painting</li>
<li>identification of gaps</li>
<li>evaluate the airflow near extractors</li>
<li>leak testing of containment systems (including Glovebag technique)</li>
<li>approximate evaluation of the speed, by means of observation of the form taken by the smoke</li>
</ul>
<p style="text-align: justify;"> </p>
<p><em><strong><span style="color: #2a7ebc;">AVAILABLE MODELS</span></strong></em></p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/02/AS1.jpg"><img class="canvas1 alignleft wp-image-1642" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/02/AS1-300x292.jpg" alt="Microsoft Word - FrontCover.doc" width="200" height="195" /></a></p>
<p><em><strong> </strong></em></p>
<p><em><strong>AS1</strong> <strong>- for point test</strong></em></p>
<p>The package contains:<br />10 tube indicator of airflow<br />the rubber bulb<br />stoppers to seal the vials</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/02/AS21.jpg"><img class="canvas1 wp-image-1643 alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/02/AS21-281x300.jpg" alt="Microsoft Word - FrontCover.doc" width="200" height="214" /></a></p>
<p>&nbsp;</p>
<p><em><strong>AS2 &#8211; for continuous monitoring<br /></strong></em><br />The package contains:<br />10 tube indicator of airflow<br />the rubber bulb<br />stoppers to seal the vials</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/smoke-test-tube/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FILTERS HOLDER BOXES</title>
		<link>https://www.aquariasrl.com/en/filters-holder-boxes/</link>
		<comments>https://www.aquariasrl.com/en/filters-holder-boxes/#comments</comments>
		<pubDate>Fri, 21 Oct 2016 13:01:56 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Filter holder boxes]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/en/?p=2227</guid>
		<description><![CDATA[For the transport of the sampled filters to the laboratories, as indicated in the method UNICHIM 285-2003, you must &#8220;Use suitable containers to prevent damage during the trip. It is preferable to use anti-static material containers and equipped with contoured cover, to ensure the locking of the circumference of the filter where the dust is not deposited&#8221;. To meet<p><a href="https://www.aquariasrl.com/en/filters-holder-boxes/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p><i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="0" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-scatolette-portafitro-con-scatolette-in-sfondo.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-scatolette-portafitro-con-scatolette-in-sfondo.jpg" alt="How to take the filter" width="467" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-scatolette-portafitro-con-scatolette-in-sfondo.jpg" target="_self" >How to take the filter</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-scatolette-portafitro.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-scatolette-portafitro.jpg" alt="How to take the filer" width="452" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-scatolette-portafitro.jpg" target="_self" >How to take the filer</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Coperchio-sagomato.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Coperchio-sagomato.jpg" alt="Contoured COVER" width="513" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Coperchio-sagomato.jpg" target="_self" >Contoured COVER</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Coperchio-sagomato.jpg" target="_self" >to ensure the locking of the filter</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Sgusci.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Sgusci.jpg" alt="Lateral SLIDES" width="552" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Sgusci.jpg" target="_self" >Lateral SLIDES</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Sgusci.jpg" target="_self" >to facilitate the filter plug with tweezers</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div></i></p>
<p>For the transport of the sampled filters to the laboratories, as indicated in the method <em><strong>UNICHIM 285-2003</strong></em>, you must &#8220;<em>Use suitable containers to prevent damage during the trip. It is preferable to use anti-static material containers and equipped with contoured cover, to ensure the locking of the circumference of the filter where the dust is not deposited&#8221;.</em></p>
<p>To meet this need AQUARIA offers its <span style="color: #2a7ebc;"><strong><em>filter cassettes</em></strong></span>, protected by utility model No. 952 465</p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong>MAIN FEATURES</strong></span></p>
<ul>
<li>available for membranes of 25 mm, 37 mm and 47 mm diameter</li>
<li>made of antistatic plastic to not electrify the membranes and bring interference in the weighing phase</li>
<li>closure that prevents the entrance of moisture and dust during transportation</li>
<li>contoured cover to ensure the locking of the filter on the circumference thus avoiding that the filter adheres to the inside of the lid and lose the sampled particulate</li>
<li>equipped, on the circumference, with two lateral slides (for right and left handed) to facilitate the filter plug with tweezers</li>
</ul>
<p>&nbsp;</p>
<p style="text-align: center;"><em><strong>Packaging: pack of 25 pieces</strong></em></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/filters-holder-boxes/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Adsorbent TUBES</title>
		<link>https://www.aquariasrl.com/en/adsorbent-tubes/</link>
		<comments>https://www.aquariasrl.com/en/adsorbent-tubes/#comments</comments>
		<pubDate>Fri, 21 Oct 2016 11:00:34 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Adsorbent tubes]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/en/?p=2211</guid>
		<description><![CDATA[NIOSH, OSHA and EPA rules involve use of adsorbent tubes for &#8220;active&#8221; sampling  of many toxic chemicals present in the atmosphere or in the duct flows as gases and vapors. From the quantity of captured substance, and determined analytically, it is possible, knowing the total volume of aspirated air, to determinate the concentration present in the<p><a href="https://www.aquariasrl.com/en/adsorbent-tubes/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p><i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="1" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/DNPH.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/DNPH.jpg" alt="DNPH Tube" width="676" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/DNPH.jpg" target="_self" >DNPH Tube</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-tappini.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-tappini.jpg" alt="Removable CAPS" width="503" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Uso-tappini.jpg" target="_self" >Removable CAPS</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="m/en/wp-content/uploads/2016/10/setto-poroso.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/setto-poroso.jpg" alt="POROUS SEPTUM" width="509" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="m/en/wp-content/uploads/2016/10/setto-poroso.jpg" target="_self" >POROUS SEPTUM</a></div>					<div class="slideshow_description"><a href="m/en/wp-content/uploads/2016/10/setto-poroso.jpg" target="_self" >in pure polyethylene</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Estrazione-setti.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Estrazione-setti.jpg" alt="Porous septum EXTRACTOR" width="662" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Estrazione-setti.jpg" target="_self" >Porous septum EXTRACTOR</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Estrazione-setti.jpg" target="_self" >Use</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Apertura-fiala-1.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Apertura-fiala-1.jpg" alt="Opening tubes" width="340" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Apertura-fiala-1.jpg" target="_self" >Opening tubes</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Apertura-fiala-2.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Apertura-fiala-2.jpg" alt="Opening tube comparison" width="583" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/Apertura-fiala-2.jpg" target="_self" >Opening tube comparison</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div></i></p>
<p>NIOSH, OSHA and EPA rules involve use of adsorbent tubes for &#8220;active&#8221; sampling  of many toxic chemicals present in the atmosphere or in the duct flows as gases and vapors. From the quantity of captured substance, and determined analytically, it is possible, knowing the total volume of aspirated air, to determinate the concentration present in the environment.</p>
<p><em><strong><span style="color: #2a7ebc;">Adsorbenti &#8220;Tubes&#8221;</span></strong></em>, produced by AQUARIA, have been developed  in compliance with D. Lgs. n. 81/08: the two ends are closed with airtight caps and therefore it is no longer necessary to break the vial before use but  just remove the caps. <br />The caps are also useful to prevent accidental breakage of vials: if dropped their diameter, slightly larger than the diameter of the vial itself, is a good protection. <br />With the aid of practical extractor (provided), you can easily rotate the porous plugs (and extract them if needed) thus removing the substrate without breaking the vial. This will prevent accidental injuries and the shedding of  glass. <br />The opening system also ensures a homogeneous and linear air inlet flow as the entry point  prevents the development of possible turbulence</p>
<p><span id="more-2211"></span></p>
<p style="text-align: justify;"><em><strong><span style="color: #2a7ebc;"><br />Fields of application:</span></strong></em></p>
<ul style="list-style-type: square;">
<li>indoor air sampling</li>
<li>outdoor air sampling</li>
<li>emissions sampling  </li>
</ul>
<p><em><strong><span style="color: #2a7ebc;"><br />FEATURES<br /></span></strong></em></p>
<ul style="list-style-type: circle;">
<li><em>Available sizes:<br /><strong>• </strong><strong>Standard:</strong></em> <br />  content of the adsorbent: 75 &#8211; 150 mg<br />  Ø internal of the tube: 5,6 mm<br />  Ø external of the tube: 8,2 mm<br /><em><strong>• Large:</strong></em><br />  content of the adsorbent: 200 &#8211; 400 mg<br />  Ø internal of the tube: 6,4 mm<br />  Ø external of the tube: 8,7 mm<br /><em><strong>• Jumbo:</strong></em><br />  content of the adsorbent: 200 &#8211; 800 mg<br />  Ø internal of the tube: 7,5 mm<br />  Ø external of the tube: 10,5 mm</li>
<li><em>Septum porous partition: i</em>n pure polyethylene (to prevent adsorption during sampling), with high porosity to minimize load losses</li>
<li>The tube ends are closed by <em>caps</em> sealed with double flap</li>
<li><em>Packaging:</em> 5, 10, 20 and 40 pieces<br />Inside the box there are adsorption tube packs of 5 pieces, each under vacuum</li>
<li>Inside the box there are<em> labels</em> on which you can note sampling data (tube ID nr. , date, sampling start and end time )</li>
</ul>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><em><strong>AVAILABLE TYPES</strong></em></span></p>
<ul style="list-style-type: disc;">
<li><em><strong>Carbon Tube</strong> </em>for VOC / BTEX sampling<br />Each pack is supplied with <em>Quality Certificate</em> and its chromatogram <br />Shelf life: 18 months<br />Available packaging: 10 and 40 pcs</li>
</ul>
<ul>
<li><em><strong>Carbon Tube attivate</strong></em> for H<sub>2</sub>S sampling<br />Each pack is supplied with <em>Quality Certificate</em> and its chromatogram <br />Shelf life: 4 months<br />Available packaging: 5 pcs</li>
</ul>
<ul>
<li><em><strong>Carbon Tube attivate</strong></em> con <em><strong>TBC</strong> </em>(ter-butilcatecolo) for methyl methacrylate sampling<br />Each pack is supplied with <em>Quality Certificate</em> and its chromatogram <br />Shelf life: 6 months<br />Available packaging: 20 pcs</li>
</ul>
<ul>
<li><em><strong>Silica Tube</strong></em> for inorganic acids, amines and amides sampling<br />Each pack is supplied with <em>Quality Certificate</em> and its chromatogram <br />Shelf life: 12 months<br />Available packaging: 5 pcs.</li>
</ul>
<ul>
<li><em><strong>Silica Tube + H<sub>2</sub>SO<sub>4</sub></strong></em> for ammonia sampling <br />Each pack is supplied with <em>Quality Certificate </em><br />Shelf life: months<br />Available packaging: 5 pcs.</li>
</ul>
<ul>
<li><em><strong>Silica Tube + TEA</strong></em> for nitrogen dioxide (NO<sub>2</sub>) sampling<br />Each pack is supplied with <em>Quality Certificate</em> <br />Shelf life: 12 months<br />Available packaging: 5 pcs<br />Disponibili nella tipologia Large e Jumbo</li>
</ul>
<ul>
<li><em><strong>Silica Tube + TEA  e Oxidant</strong></em> for nitrogen oxides (NOx) sampling<br />Each pack is supplied with <em>Quality Certificate</em> <br />Shelf life: 12 months<br />Available packaging:<br />n° 10 tubes of silica gel activated with TEA, Standard type, with content of silica 225 mg (single layer gel) <br />n° 5 tubesof oxidizing Cr<sub>2</sub>O<sub>3</sub>, Large type, with content of oxidizer 400 mg (single layer)</li>
</ul>
<ul>
<li><em><strong>DNPH Tube</strong></em> for aldehydes sampling <br />(NIOSH 2016; NIOSH 2018; EPA/625/R-96/010b con TO-11A method)<br />Each pack is supplied with <em>Quality Certificate</em> and its chromatogram <br />Shelf life: 6 months<br />Available packaging: 5 pcs</li>
</ul>
<ul>
<li><em><strong>Tenax Tube</strong></em> for odorous substances sampling and medium high boiling compounds <br />Shelf life: 12 months<br />Available packaging: 5 pcs</li>
</ul>
<ul>
<li><em><strong>XAD-2 Tube</strong></em> for very stable organic substances sampling and with high molecular weight (eg. pesticides, herbicides, PCBs, PAHs, dioxins, etc.). <br />Shelf life: 8 months<br />Available packaging: 5 pcs</li>
</ul>
<ul>
<li><em><strong>XAD-7 Tube</strong></em> for glycols, cresol, phenol sampling<br />Shelf life: 8 months<br />Available packaging: 5 pcs</li>
</ul>
<ul>
<li><em><strong>Opcalite Tube</strong> </em>for mercury sampling <br />Shelf life: 8 months<br />Contenuto in Opcalite 200 mg<br />Available packaging: 5 pcs</li>
</ul>
<p>&nbsp;</p>
<p>The following<em> <strong><span style="color: #2a7ebc;">PRECARTRIDGES </span></strong></em>are also available:</p>
<ul style="list-style-type: disc;">
<li><em><em><strong><strong><em>Precartridge of sodium sulfate </em></strong></strong></em></em>anhydrous crystals 10-60 mesh, for moisture retention<br />Na2SO4 content: 1 g <br />Available packaging: 5 pcs</li>
</ul>
<ul>
<li><em><strong>Precartridge of  iodide potassium</strong></em> for the reduction of ozone interference on aldehydes sampling, especially formaldehyde <br />Iodide potassium content:  300 mg<br />Available packaging: 5 pcs</li>
</ul>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><a style="color: #2a7ebc;" href="http://www.aquariasrl.com/en/wp-content/uploads/2016/10/DEPLIANT-Fiale-Adsorbenti-UK-rev.1.pdf" target="_blank"><strong><em>Click here to download the brochure</em></strong></a></span></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/adsorbent-tubes/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>VELOMETER e ISOBOOK</title>
		<link>https://www.aquariasrl.com/en/velometer-e-isobook/</link>
		<comments>https://www.aquariasrl.com/en/velometer-e-isobook/#comments</comments>
		<pubDate>Tue, 12 Jan 2016 10:00:47 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACCESSORIES for emission sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=1116</guid>
		<description><![CDATA[  &#160; Velometer  is a highly reliable and handy instrument realized for the control of temperature variations and ΔP in conveyed flows, to calculate their speed. Coupled with all kinds of our probes, Velometer gives an instantaneous reading of the pressure difference via a needle transducer and displays the flow temperature through a high precision display.Iit<p><a href="https://www.aquariasrl.com/en/velometer-e-isobook/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p> <i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="2" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK-2.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK-2.jpg" alt="ISOBOOK" width="509" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK-2.jpg" target="_self" >ISOBOOK</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-sinistro.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-sinistro.jpg" alt="ISOBOOK" width="261" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-sinistro.jpg" target="_self" >ISOBOOK</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-sinistro.jpg" target="_self" >Left side</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-destro.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-destro.jpg" alt="ISOBOOK" width="268" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-destro.jpg" target="_self" >ISOBOOK</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_laterale-destro.jpg" target="_self" >Right side</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_su-cavalletto.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_su-cavalletto.jpg" alt="ISOBOOK" width="348" height="500" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_su-cavalletto.jpg" target="_self" >ISOBOOK</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_su-cavalletto.jpg" target="_self" >on the tripod</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_Videata-iniziale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_Videata-iniziale.jpg" alt="ISOBOOK" width="520" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_Videata-iniziale.jpg" target="_self" >ISOBOOK</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_Videata-iniziale.jpg" target="_self" >Main menu display</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="ISOBOOK_Videata-geometria-del-condotto" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/ISOBOOK_Videata-geometria-del-condotto.jpg" alt="ISOBOOK" width="522" height="400" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="ISOBOOK_Videata-geometria-del-condotto" target="_self" >ISOBOOK</a></div>					<div class="slideshow_description"><a href="ISOBOOK_Videata-geometria-del-condotto" target="_self" >Duct geometry display</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div></i></p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Velometer.jpg"><img class=" canvas1 wp-image-1124  alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Velometer-212x300.jpg" alt="" width="153" height="217" /></a></em></strong></span></p>
<p><span style="color: #2a7ebc;"><strong><em>Velometer</em></strong> </span> is a highly reliable and handy instrument realized for the control of temperature variations and ΔP in conveyed flows, to calculate their speed. Coupled with all kinds of our probes, Velometer gives an instantaneous reading of the pressure difference via a needle transducer and displays the flow temperature through a high precision display.Iit is supplied with hose, plywood connector for connection to the thermocouple and power cord.</p>
<p>Instruments are available with different ranges:<br /><strong><em>• Velometer 20:</em></strong> range 0-25 mm H<sub>2</sub>O (<strong>code A.3007</strong>)<br /><strong><em>• Velometer 50:</em></strong> range 0-50 mm H<sub>2</sub>O (<strong>code A.3008</strong>)</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/ISOBOOK.jpg"><img class="canvas1 wp-image-1118  alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/ISOBOOK-300x225.jpg" alt="" width="170" height="128" /></a></p>
<p><span style="color: #2a7ebc;"><strong><em>ISOBOOK α</em></strong> </span>is a portable meter of emissions speed <strong><em>compliant with UNI EN 13284</em></strong> and <em><strong>16911, ISO 9096</strong>.</em></p>
<p>Thanks to electronic transducers of ΔP, temperature and pressure connected to Darcy pipes and thermocouples, the instrument allows total characterization of any emission for sampling in perfect isokinetism. It&#8217;s known that a proper definition of dust concentration in emission requires the adoption of sampling techniques providing maintenance of the isokinetic regime during the entire processus. This condition is obtained by means of an accurate and continuous measurement of the fumes speed and control of the sampling isokinetic flow rate.<br />ISOBOOKα has been conceived to fix these problems and has been realized using modern miniaturized computer systems combined with great precision and small-size measuring sensors. The heart of ISOBOOKαis a small computer which, connected to ΔP, pressure and temperature sensors, is able to acquire and check all the thermodynamic parameters of the fluid in emission, automatically calculating both fumes speed and the correct isokinetic flow. <br />The different operating menus of the program also allow the complete characterization of the chimney, according to the regulations defining both the number of sub areas and the points to be examined in the duct with the relative distance from the edge.<br />Once the preliminary velocity measurements and the calculation of the ideal nozzle diameter to fit in the sampling probe have been made, ISOBOOKα calculates the isokinetic rate that the operator shall have to adjust on his/her own air sampler. This data, fundamental for a correct sampling, is then updated on the basis of new speed measures according to a user-specified frequency, giving constant information about any new sampling condition to allow a continuous sampling control. <br />As previously said ISOBOOKα has a structured program menu briefly described</p>
<p><strong>Definition of the duct geometry <br /></strong>With this first subprogram the user can identify the emission, through the assignment of a number that will help him to retrieve stored data when necessary, and, also, to introduce the geometric data of the conduit getting from the computer calculation of the number of points to be examined and their distance from the chimney edge. The calculation program, according to UNICHIM indications, is applied both to circular ducts and rectangular ones.</p>
<p><strong>Definition of emission general parameters</strong><br />In this menu, the operator sets the peculiar characteristics of the smoke (density, mole fraction of water vapour and so on.) as well as the Darcy constant used and mediation time of the acquired data.</p>
<p><strong>Recording of leak test</strong><br />The operator can perform a leak test on his complete sampling line for a variable period till 5 minutes, as required by UNI EN 16911. The obtained data can be memorised and downloaded to PC for printing.</p>
<p><strong>Definition of average speed</strong> <br />With this subprogram the operator can measure the speed by placing the Darcy pipe at points of interest and displaying on the screen all the main parameters (ΔP, fumes and ambient temperature, speed etc.). At the end of the acquisition time it is also recorded the average speed for every single point as well as the overall average speed. <br />In the speed determination is also taken into account the <span style="text-decoration: underline;">wall effect</span> and the <span style="text-decoration: underline;">Swirl’s angle</span>, as required by the UNI EN 16911.<br />Therefore it is possible to define precisely the profile of the speed in the conduit, an indispensable condition to perform a good isokinetic sampling and characterize the emission.</p>
<p><strong>Definition of the nozzle diameter</strong> <br />This submenu provides a visual summary of the average values of the measured quantities and allows to obtain the calculation of the ideal nozzle diameter.<br />It is also possible, from a known available diameter, to obtain the calculation of the relative isokinetic flow.</p>
<p><strong>Calculation and display of the isokinetic flow <br /></strong>On this page the user sees the most important information: the isokinetic flow rate to be set on the sampler. By activating this program on the screen all the most important parameters for the isokinetic sampling are displayed including, of course, the flow rate in litres per minute calculated according to the parameters measured directly by ISOBOOK α  and updated with the frequency set by the operator. The user can run the sampling in perfect s isokinetism  just by adjusting on his own sampler the flow rate shown by  ISOBOOK   α   and the providing adjustments by following computer directions. The use of a microprocessor is essential especially for storage capacity and management: it is in fact possible to store up to 60 measurements, thus preserving the averages of all the parameters that are fully catalogued on the display with the date and time of the event and number of processed area. All data can then be printed, included in a  report, downloaded on any computer  IBM compatible and recalled at any time. ISOBOOK   α   can be powered by network (with an adapter) or battery; this feature &#8211; in addition to the small size and low weight &#8211; makes it easily to be used in any situation.</p>
<p><span style="color: #2a7ebc;"><em><strong>TECHNICAL FEATURES</strong></em></span></p>
<ul style="list-style-type: circle;">
<li><em>chassis</em>: ABS</li>
<li><em>graphic display:  </em> touch screen, 320 × 240 mm, backlit</li>
<li>automatic calculation of the nozzle or of the sampling volume</li>
<li><em>range differential pressure: </em>  0 ÷ 100 mmH2O (resolution: 0.1 mmH<sub>2</sub>O)</li>
<li><em>range absolute pressure:</em>   0 ÷ 800 mmHg (resolution: 1 mmHg)</li>
<li><em>temperature range:</em>   0 ÷ 1000 °C   (resolution: 1 °C)</li>
<li>pressure values visualization in mmH<sub>2</sub>O/mmHg or in hPascal</li>
<li>retention of all the data for 60 chimneys</li>
<li><em>RS232 interface</em> for computer data download and measured data processing</li>
<li>compatibility with forked plug thermocouples</li>
<li>compatibility with all the tubes Darcy and pitot</li>
<li><em>power: </em>rechargeable batteries</li>
<li><em>battery autonomy:</em> 12 hours</li>
<li><em>recharging batteries:</em> 6 hours</li>
<li><em>size: </em>22 x 17 x 6 cm</li>
<li><em>weight: </em>1.5 Kg</li>
<li>working temperature:  from &#8211; 10 to + 40 °C</li>
</ul>
<p><strong><em>(the instrument is supplied with a charger, a PC connection cable with USB-RS232 converter, connection cables to Darcy pipe and thermocouple, shoulder bag)</em></strong></p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;"><span style="color: #2a7ebc;"><strong><em>Click here to download the brochure</em></strong></span></p>
<p><strong> </strong></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/velometer-e-isobook/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DUST AND GAS PROBES</title>
		<link>https://www.aquariasrl.com/en/sonde-per-campionamento-polveri-e-gas/</link>
		<comments>https://www.aquariasrl.com/en/sonde-per-campionamento-polveri-e-gas/#comments</comments>
		<pubDate>Mon, 11 Jan 2016 16:22:07 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACCESSORIES for emission sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=1164</guid>
		<description><![CDATA[PROBE FOR DUST SAMPLING Simple   monotube  probe (AISI 316 steel or titanium) complete with sliding tube, basket/filter holders adapter for the use of membranes Ø 47 mm and flange 90 mm dimeter.   Length 1 m. &#160; Isokinetic   composite   probe  (AISI 316 steel or titanium), with flange diameter 90 mm. This model, which includes both the sample probe and the Darcy tube and<p><a href="https://www.aquariasrl.com/en/sonde-per-campionamento-polveri-e-gas/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="3" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo-principale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo-principale.jpg" alt="Isokinetic composite probe" width="500" height="165" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo-principale.jpg" target="_self" >Isokinetic composite probe</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo_particolare.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo_particolare.jpg" alt="Isokinetic composite probe" width="569" height="239" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo_particolare.jpg" target="_self" >Isokinetic composite probe</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-bitubo_particolare.jpg" target="_self" >Sampling tube and Pitot tube</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo.jpg" alt="Simple monotube probe" width="1403" height="354" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo.jpg" target="_self" >Simple monotube probe</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo_particolare.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo_particolare.jpg" alt="Simple monotube probe" width="537" height="370" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo_particolare.jpg" target="_self" >Simple monotube probe</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-mototubo_particolare.jpg" target="_self" >with nozzles</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-multiforo.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-multiforo.jpg" alt="Gas multi-hole probe" width="1052" height="354" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-multiforo.jpg" target="_self" >Gas multi-hole probe</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-multiforo_particolare.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-multiforo_particolare.jpg" alt="Gas multi-hole probe" width="537" height="271" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda-multiforo_particolare.jpg" target="_self" >Gas multi-hole probe</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div>
<p><span style="color: #2a7ebc;"><em><strong>PROBE FOR DUST SAMPLING</strong></em></span></p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Sonda-mototubo.jpg"><img class=" canvas1 alignleft wp-image-1171" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Sonda-mototubo-300x76.jpg" alt="Sonda mototubo" width="292" height="74" /></a>Simple   <em><strong>monotube  probe </strong></em>(AISI 316 steel or titanium) complete with sliding tube, basket/filter holders adapter for the use of membranes Ø 47 mm and flange 90 mm dimeter.   Length 1 m.</p>
<p>&nbsp;</p>
<p><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Sonda-bitubo-principale.jpg"><img class=" canvas1 alignleft wp-image-1176" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Sonda-bitubo-principale-300x99.jpg" alt="Sonda bitubo (principale)" width="292" height="96" /></a></em></strong></p>
<p><em><strong>Isokinetic   composite   probe</strong></em>  (AISI 316 steel or titanium), with flange diameter 90 mm. This model, which includes both the sample probe and the Darcy tube and thermocouple, is accompanied by a universal holder that allows both the use of the classic basket and, adding a simple adapter, the use of membranes Ø 47 mm. Particular attention has been paid to the sampling curve which, thanks to its geometric characteristics, avoids the deposition of the dust before the filtering support.<br />Probes are available in different lengths: 50 &#8211; 100 &#8211; 150 &#8211; 200 cm</p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Ugelli.jpg"><img class=" canvas1 alignleft wp-image-1175" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Ugelli-300x244.jpg" alt="Ugelli" width="192" height="156" /></a></em></strong></span></p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em>Conical nozzles</em></strong></span> steel or titanium (diameters between 3 and 16 mm)</p>
<p>&nbsp;</p>
<p><strong><em> </em></strong></p>
<p><strong><em> </em></strong><strong><em> </em></strong></p>
<p><strong><em> <a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Cestelli.jpg"><img class=" canvas1 alignleft wp-image-1166" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Cestelli-300x182.jpg" alt="Cestelli" width="193" height="117" /></a></em></strong></p>
<p><span style="color: #2a7ebc;"><strong><em>Basket </em></strong></span>for silica wool in steel or titanium</p>
<p>&nbsp;</p>
<p> <strong><em> </em></strong></p>
<p><span style="color: #2a7ebc;"><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Portaditali.jpg"><img class=" canvas1 alignleft wp-image-1167" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Portaditali-300x246.jpg" alt="Portaditali" width="191" height="157" /></a></em></strong></span></p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em>Thimble holder </em></strong></span> for glass fiber thimbles (30 x 100) <br /> Thimble holder for ceramic thimbles (25.5 x 80)</p>
<p><strong><em> </em></strong></p>
<p><strong><em> </em></strong></p>
<p><strong><em> </em></strong><strong><em> </em></strong></p>
<p><span style="color: #2a7ebc;"><strong><em>PROBE FOR gaseous compounds SAMPLING</em></strong></span></p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Sonda-multiforo.jpg"><img class=" canvas1 alignleft wp-image-1173" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Sonda-multiforo-300x101.jpg" alt="Sonda multiforo" width="193" height="65" /></a></p>
<p><em><strong>Gas multi-hole probe</strong></em>  compliant with <strong>Unichim standards</strong>. Made of stainless steel AISI 316. Complete with hose for pneumatic connection and threaded connection for isokinetic probe inclusion in the flanges.</p>
<p>Available 1 or 2 meters long.</p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Portafiala-per-emissioni.jpg"><img class=" canvas1 alignleft wp-image-1168" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Portafiala-per-emissioni-182x300.jpg" alt="Portafiala per emissioni" width="103" height="170" /></a><span style="color: #2a7ebc;"><strong><em><br />Tube holder</em></strong></span> made of aluminum suitable for containing Large and Jumbo vials. It can be used on the sampling line in case solvents vapors sampling is carried out with steel probe. Complete with hose for connection to the sampling tube.</p>
<p><strong><em> </em></strong></p>
<p><strong><em> </em></strong></p>
<p><strong><em> </em></strong></p>
<p><span style="color: #2a7ebc;"><strong><em>ACCESSORIES FOR PNEUMATIC CONNECTION OF DIFFERENT SAMPLING DEVICES</em></strong></span></p>
<p><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Tubo-PVC.jpg"><img class="canvas1 wp-image-1080 alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Tubo-PVC-300x201.jpg" alt="Tubo PVC" width="191" height="128" /></a></em></strong></p>
<p>&nbsp;</p>
<p><em><strong>PVC netted hose</strong> </em>for connecting sampling systems to the sampler: 2, 4 and 10 mt lenght</p>
<p><strong> </strong></p>
<p>&nbsp;</p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/sonde-per-campionamento-polveri-e-gas/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TITANIUM HEATED PROBE  FOR MICROPOLLUTANTS</title>
		<link>https://www.aquariasrl.com/en/sonda-in-titanio-riscaldata-per-microinquinanti/</link>
		<comments>https://www.aquariasrl.com/en/sonda-in-titanio-riscaldata-per-microinquinanti/#comments</comments>
		<pubDate>Fri, 08 Jan 2016 14:38:20 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACCESSORIES for emission sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=1153</guid>
		<description><![CDATA[The components of the probe in contact with the polluted are made entirely of titanium and the measurement of the   sample temperature, as required by  UNI EN 1948  occurs within the sampling chamber downstream the filter media. The  probe, protected by utility model, through a particular removable insert positioned within the sampling chamber, allows the operator to interchange the sampling media<p><a href="https://www.aquariasrl.com/en/sonda-in-titanio-riscaldata-per-microinquinanti/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p><i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="4" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/sonda-completa.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/sonda-completa.jpg" alt="HEATED PROBE" width="866" height="370" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/sonda-completa.jpg" target="_self" >HEATED PROBE</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Puntale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Puntale.jpg" alt="HEATED PROBE" width="705" height="370" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Puntale.jpg" target="_self" >HEATED PROBE</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Puntale.jpg" target="_self" >Front</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_estrazione-ditale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_estrazione-ditale.jpg" alt="Thimble holder removal" width="479" height="370" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_estrazione-ditale.jpg" target="_self" >Thimble holder removal</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_portaditale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_portaditale.jpg" alt="Thimble holder" width="411" height="600" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_portaditale.jpg" target="_self" >Thimble holder</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_parte-posteriore-con-termocoppia.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_parte-posteriore-con-termocoppia.jpg" alt="HEATED PROBE" width="530" height="370" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_parte-posteriore-con-termocoppia.jpg" target="_self" >HEATED PROBE</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_parte-posteriore-con-termocoppia.jpg" target="_self" >Back</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_termocoppia.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_termocoppia.jpg" alt="Thermocouple" width="660" height="370" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_termocoppia.jpg" target="_self" >Thermocouple</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_fondo.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_fondo.jpg" alt="Closing stopper" width="497" height="500" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Sonda_fondo.jpg" target="_self" >Closing stopper</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/centralina-controllo.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/centralina-controllo.jpg" alt="Temperature control unit microprocessor" width="600" height="500" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/centralina-controllo.jpg" target="_self" >Temperature control unit microprocessor</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div></i><br />The components of the probe in contact with the polluted are made entirely of titanium and the measurement of the   sample temperature, as required by  <em><strong>UNI</strong></em> <em><strong>EN 1948 </strong></em> occurs within the sampling chamber downstream the filter media.</p>
<p>The  probe, <em><strong>protected by utility model</strong></em>, through a particular removable insert positioned within the sampling chamber, allows the operator to interchange the sampling media easily (filter &#8211; thimble &#8211; basket) without removing the probe from its holder in the chimney.</p>
<p>In the rear closing cap of the sampling chamber, always made of titanium, are located the housing of the thermocouple, the hose connection fitting for dust sampling and other three connections that, when not in use, are closed by removable plugs and replaceable with titanium hose.</p>
<p>The probe is heated by resistors connected to a temperature control framework with IP microprocessor 65. The set temperature adjustment is ensured by the thermocouple within the sampling chamber and connected to the temperature control framework.</p>
<p>For the leak test, which must be carried out before each sampling, you should use the blind nozzle (supplied) by screwing it on the terminal part of the curve.</p>
<p>After sampling, and extracting the insert with the sampling device, the operator can clean the probe for retrieving micropollutants still inside it, by closing both the sampling chamber (using the special blind plate supplied ) and the curve nozzle holder, as already described.</p>
<p>The probe is supplied with:</p>
<ul style="list-style-type: circle;">
<li><em><strong>Sampling room </strong></em>in titanium, provided with a jack for connection to the control unit, equipped with an external jacket in stainless steel AISI 316: between the external jacket and the sampling chamber is located wrapped resistance heating.<br />The sampling room is equipped with:<br />- titanium insert sample devices holder <br />- filter holder, thimble holder, rack holders for the insert abovementioned (all devices are made of titanium) <br />- closing plate for sample chamber made of titanium, designed for 4 hose connections and a thermocouple attack <br />- blind plate closing the sample chamber titanium probe for washing <br />- titanium flange and teflon ring nut for the tightening of the sampling chamber with the  above-mentioned  plates<br />- thermocouple for measuring the temperature in the sample chamber and, as provided for by the norm, behind the filter media and equipped with connection cable to the control unit <br />- 4 hoses<br />- set of gaskets <br />- 2 meshes of titanium filter holder</li>
<li><em><strong>Sampling tube</strong></em> for chimney equipped with an external jacket in stainless steel AISI 316: between the external jacket and the sampling tube is wrapped resistance for heating provided with attachment to the control unit. <br />The tube is supplied with: <br />- access to the sample chamber <br />- curved nozzle holder <br />- heating  resistance with connector <br />- stainless steel flange (Ø 90 mm) with sliding sleeves <br />- termocoppia<br />- thermocouple</li>
</ul>
<p>Probes are available in different lengths: 50 &#8211; 100 &#8211; 150 &#8211; 200 cm</p>
<p>The sampling tubes of the heated probes are interchangeable: a 50 cm probe can easily be converted into a 2 meters probe simply purchasing the tube of the desired length.</p>
<p>&nbsp;</p>
<p><span style="color: #333399;"><strong>ACCESSORIES</strong></span> </p>
<ul style="list-style-type: disc;">
<li><em><strong><span style="color: #2a7ebc;">Temperature control unit microprocessor</span></strong></em>, protection class IP 65 consisting of: <br />- IP 30 protection case  <br />- power cable 3 m   <br />- programmable alarm contact  (3A MAX) <br />- auto-tuning function  <br />- logic PID (Proportional Integrated Derivative)  <br />- digital display  <br />- static control to wave zero crossing trains   <br />- settable temperature up to 1000  C (however, temperatures above 800 °C can damage the probe)  <br />- dimensions: 220 x 200 x 250 mm (WxDxH)  </li>
<li><em><strong><span style="color: #2a7ebc;">Nozzles</span></strong></em> tapered titanium (from 4 to 10 mm)</li>
<li><em><strong><span style="color: #2a7ebc;">Basket</span></strong></em> of titanium for silica wool</li>
<li><span>Wooden<strong style="color: #2a7ebc; font-style: italic;"> transport and containment box </strong>equipped with handle and wheels, with spring connections for nozzles and segmented container for accessories</span></li>
</ul>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/sonda-in-titanio-riscaldata-per-microinquinanti/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DEHUMIDIFIER CYLINDER and HIGH EFFICIENCY CONDENSER</title>
		<link>https://www.aquariasrl.com/en/velometer-e-isobook-2/</link>
		<comments>https://www.aquariasrl.com/en/velometer-e-isobook-2/#comments</comments>
		<pubDate>Fri, 08 Jan 2016 13:20:39 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACCESSORIES for emission sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=1134</guid>
		<description><![CDATA[&#160; Dehumidifier cylinder (diam. 9 cm &#8211; h. 23 cm). It is a solid Plexiglas cartridge loadable with common silica gel with indicator dye or with activated carbon, suitable to hold any condense whose content could be corrosive and therefore may damage the pump in case of accidental aspiration (Code A.3042) Silica gel with turning yellow-green indicator<p><a href="https://www.aquariasrl.com/en/velometer-e-isobook-2/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Cilindro-deumidificatore.jpg"><img class=" canvas1  wp-image-1132  alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Cilindro-deumidificatore-158x300.jpg" alt="" width="140" height="266" /></a></em></strong></p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em>Dehumidifier cylinder </em></strong></span>(diam. 9 cm &#8211; h. 23 cm). It is a solid Plexiglas cartridge loadable with common silica gel with indicator dye or with activated carbon, suitable to hold any condense whose content could be corrosive and therefore may damage the pump in case of accidental aspiration (Code A.3042)</p>
<p><em><strong><span style="color: #2a7ebc;">Silica gel</span></strong></em> with turning yellow-green indicator dye  Pack: 1 kg (Code A.3091)</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;"><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Condensatori.jpg"><img class="canvas1 wp-image-1133 alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Condensatori-300x275.jpg" alt="Condensatori" width="173" height="159" /></a></p>
<p><span style="color: #2a7ebc;"><strong><em>High efficiency condenser. </em></strong></span>This device has been designed both for maximum smoke cooling as well as efficient condensate collection. Cooling is obtained by means of a Pyrex glass serpentine, that can be cooled also with water or liquid in forced circulation, while a glass ampoule ensures condensate liquid collection. The whole system is set in a solid Plexiglas cylinder and it is connected to the pump via hose connector.</p>
<p>2 litres condenser (Code A.3060) and 1 litre condenser (Code C.2011) are available</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/velometer-e-isobook-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>COOLER CASE and COOLER BOX</title>
		<link>https://www.aquariasrl.com/en/valigia-termica-e-frigocongelatore/</link>
		<comments>https://www.aquariasrl.com/en/valigia-termica-e-frigocongelatore/#comments</comments>
		<pubDate>Thu, 07 Jan 2016 16:33:30 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACCESSORIES for emission sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=1104</guid>
		<description><![CDATA[&#160; &#160; Cooler case complete of stainless steel AISI 316 basket for n° 4 impingers. This solution allows to maintain the reagents in the impingers at a low temperature extending efficiency performance. The cooling can be done via pats of ice or by filling with cold water and ice (Code A.3055) &#160; &#160; Portable cooler box  with<p><a href="https://www.aquariasrl.com/en/valigia-termica-e-frigocongelatore/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="5" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Valigia-portagorgogliatori.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Valigia-portagorgogliatori.jpg" alt="COOLER CASE" width="701" height="470" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Valigia-portagorgogliatori.jpg" target="_self" >COOLER CASE</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Cestello-portagorgogliatori.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Cestello-portagorgogliatori.jpg" alt="Basket for impingers" width="556" height="570" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Cestello-portagorgogliatori.jpg" target="_self" >Basket for impingers</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-chiuso.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-chiuso.jpg" alt="COOLER BOX" width="414" height="311" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-chiuso.jpg" target="_self" >COOLER BOX</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-chiuso.jpg" target="_self" >Closed</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-aperto.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-aperto.jpg" alt="COOLER BOX" width="331" height="363" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-aperto.jpg" target="_self" >COOLER BOX</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Frigo-aperto.jpg" target="_self" >Open</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Valigia-portagorgogliatori.jpg"><img class=" canvas1 alignleft wp-image-1102" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Valigia-portagorgogliatori-300x201.jpg" alt="Valigia termica" width="201" height="135" /></a>Cooler case </em></strong></span>complete of stainless steel AISI 316 basket for n° 4 impingers. This solution allows to maintain the reagents in the impingers at a low temperature extending efficiency performance. The cooling can be done via pats of ice or by filling with cold water and ice <em>(Code A.3055) </em></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Frigo-chiuso.jpg"><img class="canvas1 wp-image-1100 alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Frigo-chiuso-300x225.jpg" alt="Frigo congelatore" width="200" height="150" /></a></p>
<p>Portable<span style="color: #2a7ebc;"><strong><em> cooler box</em></strong></span>  with the following characteristics:</p>
<p>• Gross capacity: 35 litres<br />• Weight: 10 kg<br />• Power: 60 Watt<br />• Voltage: 12 to 24 volts<br />• Thermostatic adjustment: 1 ° to 5 °C (up to 30° below the ambient temperature)</p>
<p>Via hose connectors, placed in the inlet and outlet, the refrigerator can be connected with the entire sampling line. Internally it is predisposed to the housing of the 4 impingers needed for the sampling.<br />It can also be used for samples transport as it is rechargeble via car battery <em>(Code A.3056)</em></p>
<p><strong><em><a href="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Gorgogliatore-A-del-DPCM-28-03-1983.jpg"><img class="canvas1 wp-image-1101  alignleft" src="http://www.aquariasrl.com/h3o/wp-content/uploads/2016/01/Gorgogliatore-A-del-DPCM-28-03-1983-107x300.jpg" alt="Gorgogliatore A del DPCM 28-03-1983" width="77" height="216" /></a></em></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="color: #2a7ebc;"><strong><em>Impinger </em></strong> </span>type A for inorganic gases sampling in emission in compliance with Unichim method and DPCM 28/03/83 <em>(Code A.2013)</em></p>
<p><strong> </strong></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/valigia-termica-e-frigocongelatore/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
