FLOW ACTIVA_VF e VE Standard e Plus (vertical laminar flow)


The cabinet FLOW ACTIVA VF has been developed for the comprehensive protection of operator, product and environment during the manipulation of microorganisms at low biological risk (category 1 and 2).

In Flow Activa, Class II Type A1 and A2 (ex A and B3), the decontaminated air from the HEPA filter of downflow goes down with laminar flow into the work area, crosses the plan, is mixed with outdoor air, that enters into the cabin through the front opening in the front area of the worktop. The contaminated air is aspirated from the fan motor at the top of the cabin and conveyed into a plenum: here about 70% is sent again into the working area with absolute filtration and the remaining 30% is expelled to the outside, directly (in Standard models) or after absolute filtration (in Plus models).
The quantity of expelled air is replenished with an equal amount of ambient air asucked through the front opening, creating a barrier to protect the operator.

Flow Activa plus VF e VE 120 - 150 e 180 are Biohazard models and they have TUV certification according to UNI EN 12469 (cert. n° ZI 10 09 62765 004 e n°Z1 10 09 62765 003)


- External chassie in steel sheet (thickness 12/10), epoxy paint
- Inside botton pannel in stainless steel AISI 304 scotch-brite
- Perforated worktop in stainless steel AISI 304 scotch-brite, divided into four segments easily removable and sterilized in the autoclave
- Large liquid collection tank below the worktop to collect accidental spills
- Side panels in polycarbonate to control operations under the cabinet
- Unbreakable tempered glass front (thickness 6 mm), with acoustic alarm of incorrect operating conditions:
   ° FLOW ACTIVA VF: front window openable flap
   ° FLOW ACTIVA VE: front window openable by vertical motorized latch, equipped of  sealing   for glass in complete closure
- Front opening height:
   ° FLOW ACTIVA VF: 200 mm (in working position)
   ° FLOW ACTIVA VE: variable, with electronic control 
Fan motor with electronic control able to compensate for losses due to the gradual clogging of the HEPA filters 
- Possibility to channel outside the exhaust air, if required, by the local of installation with the optional collar diameter of 250 mm)
- Plenum seal dynamic
- Equipped with HEPA filters in class H14, removable from the front of the machine, with efficiency greater than 99.995 MPPS on particles with diameter equal or greater than 0.3 micron which complies with EN 1822.
   ° FLOW ACTIVA VF Standard: n° 1 HEPA filter in downflow
   ° FLOW ACTIVA VF e VE Plus: n° 2 HEPA filters (one in downflow and one in exhaust)
- Sockets for DOP test on the flow of supply and exhaust
- Automatic regulation of downflow air speed and of exhaust air (front barrier)
- Exhaust air flow: 300 m3/h min - 600 m3/h Max (depending on model)
- Noise level: < 60 dBA
- Increase heat: <4 ° C
- Average speed LAF: > 0.40 m / sec (adjustable by the customer)
- Average speed barrier: > 0.40 m / sec (can be changed by customer)
- Light on top: > 800 lux
- Power consumption (excluding internal socket and optional):
   ° models FLOW ACTIVA VF
     mod.   90: 0,33 KW     
     mod. 120: 0,47 KW 
     mod. 150: 0,47 KW     
     mod. 180: 0,63 KW
   ° models FLOW ACTIVA VE
     mod.   90: 0,48 KW
     mod. 120: 0,62 KW
     mod. 150: 0,63 KW
     mod. 180: 0,78 KW
- Power supply:  230 V; 50 Hz
- External dimensions (support not included):
   ° mod.   90:  980 x 795 x 1400 mm (L x W x H)
   ° mod. 120:1285 x 795 x 1400 mm (L x W x H)
   ° mod. 150:1465 x 795 x 1400 mm (L x W x H)
   ° mod. 180:1890 x 795 x 1400 mm (L x W x H)
- Internal dimensions:
   ° mod.   90:  970 x 570 x 635 mm (L x W x H)
   ° mod. 120:1275 x 570 x 635 mm (L x W x H)
   ° mod. 150:1455 x 570 x 635 mm (L x W x H)
   ° mod. 180:1880 x 570 x 635 mm (L x W x H)
- Net weight:
   ° mod.   90:  174 kg (VF) ; 180 kg (VE)
   ° mod. 120:  224 kg (VF) ; 234 kg (VE)
   ° mod. 150:  245 kg (VF) ; 255 kg (VE)
   ° mod. 180:  275 kg (VF) ; 285 kg (VE)


CONTROL BOARD

On the control  panel,  which contains the electronic board controlled by a new generation microprocessor, are present:
- general switch with button O/I light
- soft touch membrane keyboard in static protection
- digital display with real-time reading  of  the speed of vertical laminar flow and of the front barrier in meters/second
- operation time U.V. lamp countdown that can be set by the client with auto power off at the end of cycle, from 1 to 999 minutes
- electronic digital hour meter of the operating of the machine
- electronic digital hour meter of the operating of the U.V. lamp (if installed)
- early warning of:
   * reached maximum time limit of use HEPA filter installed, with indication of the need to replace next
   * exhaustion of germicidal capacity of UV lamp, with indication of the need to replace next
- visual and acoustic alarm for:
   * glass front in wrong position
   * filter clogging
   * malfunction of fan motor/s
   * speed of air LAF or BARRIER insufficient or too high
- Buttons:
   * activation fan/s 
   * UP/DOWN electric front window (only for mod. Flow Activa VE Plus)
   * drive emergency solenoid valve on gas tap (if installed) 
   * start fluorescent lamp and UVC lamp (if installed) interlocked with each other
   * internal standard power outlet (230V/50Hz)
- Emergency button for the possibility of increasing the flow rate of air expulsion and work plan (indirect increase of barrier protection operator)


COMPLIANCE

ISO 5 (ex Federal Standard 209D)
UNI EN 12469
Standard EN 1822 (HEPA filters)
Italian Electrotechnical Committee (IEC 66.5)
CEI 62.25 for Class 1 equipment permanently installed
UNI-CIG
Recommendations made by WHO and the National Commission on AIDS of the Ministry of Health on the safety of health workers.