<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aquaria Srl &#187; ACTIVE SAMPLERS for MICROBIOLOGICAL air sampling</title>
	<atom:link href="https://www.aquariasrl.com/en/category/active-samplers-for-microbiological-air-sampling/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.aquariasrl.com/en</link>
	<description>Instruments for environmental monitoring</description>
	<lastBuildDate>Mon, 26 May 2025 07:39:01 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.26</generator>
	<item>
		<title>Active sampler for microbiological air sampling “Microflow alfa”</title>
		<link>https://www.aquariasrl.com/en/campionatore-attivo-per-il-campionamento-microbiologico-dellaria-microflow-alfa/</link>
		<comments>https://www.aquariasrl.com/en/campionatore-attivo-per-il-campionamento-microbiologico-dellaria-microflow-alfa/#comments</comments>
		<pubDate>Thu, 17 Dec 2015 15:24:52 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACTIVE SAMPLERS for MICROBIOLOGICAL air sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=340</guid>
		<description><![CDATA[Microflow α has been developed for bio-aerosol (eg.: fungal spores, bacterial cells, etc.) sampling. This type of sampling allows to verify and measure the presence of microorganism potentially harmful, in order to perform an exposure assessment, and identify the source of pollution to adopt a containment plan. Sampling principle: The sample is drawn through a pierced sampling<p><a href="https://www.aquariasrl.com/en/campionatore-attivo-per-il-campionamento-microbiologico-dellaria-microflow-alfa/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;"><i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="0" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_Presentazione.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_Presentazione.jpg" alt="MICROFLOW" width="2152" height="1393" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_Presentazione.jpg" target="_self" >MICROFLOW</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_kit-completo.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_kit-completo.jpg" alt="MICROFLOW" width="680" height="474" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_kit-completo.jpg" target="_self" >MICROFLOW</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_kit-completo.jpg" target="_self" >Kit</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Su-cavalletto.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Su-cavalletto.jpg" alt="MICROFLOW" width="350" height="708" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Su-cavalletto.jpg" target="_self" >MICROFLOW</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Su-cavalletto.jpg" target="_self" >on the tripod</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_accessorio-per-campionamento-in-condotte.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_accessorio-per-campionamento-in-condotte.jpg" alt="MICROFLOW" width="2187" height="1677" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_accessorio-per-campionamento-in-condotte.jpg" target="_self" >MICROFLOW</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_accessorio-per-campionamento-in-condotte.jpg" target="_self" >accessory for sampling in conduct not under pressure</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/accessorio-per-posizionamento-verticale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/accessorio-per-posizionamento-verticale.jpg" alt="Accessory for vertical position" width="568" height="500" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/accessorio-per-posizionamento-verticale.jpg" target="_self" >Accessory for vertical position</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_su-accessorio-per-posizionamento-verticale.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_su-accessorio-per-posizionamento-verticale.jpg" alt="MICROFLOW" width="525" height="700" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_su-accessorio-per-posizionamento-verticale.jpg" target="_self" >MICROFLOW</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_su-accessorio-per-posizionamento-verticale.jpg" target="_self" >on vertical suport</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_-flambatore.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_-flambatore.jpg" alt="Pencil torch" width="581" height="386" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_-flambatore.jpg" target="_self" >Pencil torch</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Calibratore-Setra.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Calibratore-Setra.jpg" alt="Digital calibration kit" width="707" height="728" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Calibratore-Setra.jpg" target="_self" >Digital calibration kit</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div></i></p>
<p style="text-align: justify;"><span style="color: #2a7ebc;"><em><strong>Microflow α</strong></em> </span>has been developed for bio-aerosol (eg.: fungal spores, bacterial cells, etc.) sampling. This type of sampling allows to verify and measure the presence of microorganism potentially harmful, in order to perform an exposure assessment, and identify the source of pollution to adopt a containment plan<span style="color: #2a7ebc;">.<br /></span></p>
<p style="text-align: justify;"><em><strong><span style="color: #2a7ebc;">Sampling principle:</span></strong></em> The sample is drawn through a pierced sampling head at constant speed for a variable time, depending on the nature of the environment to be monitored. The flow air is conveyed on the surface of a plate containing the culture media suitable for the microbiological research desired. Once the sampling is finished, the plate is removed and put under incubation. At the end of incubation time it will be possible to count the developed colonies for cm<sup>2</sup> and to evaluate the contamination level.</p>
<p style="text-align: justify;"><em><strong><span style="color: #2a7ebc;"><br />Application fields:</span></strong></em></p>
<ul style="list-style-type: square;">
<li style="text-align: justify;">security restricted areas</li>
<li style="text-align: justify;">hospital</li>
<li style="text-align: justify;">pharmaceutical industries</li>
<li style="text-align: justify;">food and dairy company</li>
<li style="text-align: justify;">air treatment systems</li>
<li style="text-align: justify;">water purification implants</li>
<li style="text-align: justify;">working environments subject to controls as required by D.L. 155/97 (HACCP) and D.L. 81/2008</li>
</ul>
<p style="text-align: justify;"> <br /><em><strong>The instrument has been developed in </strong><strong><span style="color: #2a7ebc;">compliant</span></strong></em> with:</p>
<ul style="list-style-type: square;">
<li style="text-align: justify;">norm UNI EN ISO 14698-1:2004</li>
<li style="text-align: justify;">method UNICHIM n°1962-2</li>
</ul>
<p style="text-align: justify;"><span style="color: #2a7ebc;"><em><strong><br />TECHNICAL FEATURES</strong></em></span></p>
<ul style="list-style-type: circle;">
<li style="text-align: justify;"><em>Chassie</em> in disinfectable polyurethane; furthermore, the inside of the chassis is clad with an antibacterial silver paint</li>
<li style="text-align: justify;"><em>Alphanumeric display</em> for the menu presentation and displaying all &#8220;step by step&#8221; operations. The different menus can be visualized in one of the following five languages: Italian, English, French, German and Spanish</li>
<li style="text-align: justify;">Display<em> alarm</em> warning (i.e. low battery level, etc.)</li>
<li style="text-align: justify;"><em>Control panel</em> with membrane keyboard</li>
<li style="text-align: justify;"><em>Sampling head</em> in anodised aluminium, that can be sterilised by autoclave, with twist lock fixing<em><strong><br />     • Microflow α 60:</strong></em> sampling head with 219 conical holes (ø 1 mm)<br /><strong><em>     • Microflow α 90c:</em></strong> sampling head with 380 conical holes (ø 1 mm)</li>
<li style="text-align: justify;"><em>Anodised and sterilisable aluminium plate support</em> structure equipped with steel spring plate holders
<ul style="list-style-type: disc;">
<li style="text-align: justify;"><em><strong>Microflow α 60:</strong></em> can host a contact plate with diameter of 60 ± 2 mm</li>
<li style="text-align: justify;"><strong><em>Microflow α 90c:</em></strong> can host a Petri dish with diameter of 90 ± 2 mm</li>
<li style="text-align: justify;"><strong><em>Microflow α 60/90c:</em></strong> can host both Petri dish with diameter of 90 ± 2 mm and contact plate with diameter of 60 ± 2 mm, simply replacing the mechanical unit</li>
</ul>
</li>
<li style="text-align: justify;">Bright<em> ON/OFF LEDs</em> for checking the instrument activity</li>
<li style="text-align: justify;"><em>Flow rate:</em> 30 – 60 – 90 – 100 – 120 l/min. <strong>The flow rates are calibrated using a calibration system, which has been developed by Polytechnic of Milan &#8211; Department of Aerospatiale engineering (report n°377/2003) and certificated by I.N.RI.M. of Turin (certificated n°10-0114-01/2010)</strong></li>
<li style="text-align: justify;"><em>Calibration control function</em> (with dedicated key)</li>
<li style="text-align: justify;">The <em>quantity of sampled air</em> is programmable from 1 litre up to 2000 litres with steps of 1 litre. Furthermore, it is possible to set a manual sampling in case it is necessary to suck for an indeterminate period.</li>
<li style="text-align: justify;">Possibility to set a <em>sequential sampling</em> <strong>as indicated by guidelines of ISPESL</strong></li>
<li style="text-align: justify;">Set of <em>delayed start</em></li>
<li style="text-align: justify;"><em>Remote control</em> for the start of the sampling (able to pass through the glass)</li>
<li style="text-align: justify;"><em>Memorize</em> of 160 samplings (date, time, sampled volume and sampling flow rate) and USB port to download the data on the PC. WINDOWS compatible (<strong>in compliance with GLP &#8211; <em>Good Laboratory Practice</em> &#8211; and GMP &#8211; <em>Good Manufacturing Practice</em></strong>)</li>
<li style="text-align: justify;"><em>Rechargeable battery</em> (without memory effect) with approximately 4 &#8211; 5 hours of autonomy (for a continuous sampling with a flow rate of 1,5 l/s)</li>
<li style="text-align: justify;"><em>Battery charger</em> (220 V) with a complete recharge in approximately 4 hours</li>
<li style="text-align: justify;">Possibility of <em>power supply</em> for short periods</li>
<li style="text-align: justify;"><em>In <strong>compensated</strong> models:</em> compensation of the flow rate at the variation of the battery supply voltage and contingent load loss due to plates with different dimensions from the calibration plate.<strong> With these models it is possible to use any kind of Petri Plate in the market</strong>. In case that the compensation system is not able to keep the flow rate constant, the system switches on overflow mode and the instrument will lockup.</li>
<li style="text-align: justify;"><em>Dimensions:</em> 310 x 130 x 170 mm (length x width x high)</li>
<li style="text-align: justify;"><em>Weight:</em> 1,9 kg</li>
<li style="text-align: justify;"><em>Operating conditions:<br /></em>   Temperature: 0 – 50°C<br />   Relative humidity: 20- 80% without condense</li>
</ul>
<p style="text-align: justify;"><em><strong>The</strong></em><span style="color: #2a7ebc;"><em><strong> kit is complete of</strong></em></span>:</p>
<ul style="list-style-type: disc;">
<li style="text-align: justify;">carrying case</li>
<li style="text-align: justify;">MICROFLOW air sampler</li>
<li style="text-align: justify;">additional alluminium samplig head (only for Microflowa 60 and 90c kit)</li>
<li style="text-align: justify;">battery charger</li>
<li style="text-align: justify;">IR remote control</li>
<li style="text-align: justify;">Torch pen</li>
<li style="text-align: justify;">User manual in English language</li>
<li style="text-align: justify;">Test report</li>
</ul>
<p style="text-align: justify;">  </p>
<p style="text-align: justify;"><span style="color: #333399;"><strong>ACCESSORIES</strong></span></p>
<ul style="list-style-type: disc;">
<li style="text-align: justify;"><span style="color: #2a7ebc;"><em><strong>Tripod</strong> </em></span> type Master, high max  3,66 m</li>
<li style="text-align: justify;"><em><strong><span style="color: #2a7ebc;">Stainless steal sampling head</span></strong></em></li>
<li style="text-align: justify;"><span style="color: #2a7ebc;"><em><strong>USB interface</strong></em></span> for PC data download, complete of software for the transmission and data manage in compliance with<em><strong> UNICHIM manual n°1962</strong></em></li>
<li style="text-align: justify;">Accessory for per <em><strong><span style="color: #2a7ebc;">sampling in conduct not under pressure </span></strong></em></li>
<li style="text-align: justify;">Accessory for the<span style="color: #2a7ebc;"><em><strong> positioning </strong></em></span>of the sampler<span style="color: #2a7ebc;"><em><strong> </strong></em></span> <span style="color: #2a7ebc;"><span style="color: #2a7ebc;"><em><strong>in vertical position </strong></em></span></span></li>
<li style="text-align: justify;"><span style="color: #2a7ebc;"><em><strong>Digital calibration kit</strong> </em><span style="color: #000000;">&#8220;M</span></span>icrocontrol&#8221; composed by a digital differential pressure indicator, connection tube and conversion table</li>
</ul>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;"><span style="text-decoration: underline;"><span style="color: #2a7ebc; text-decoration: underline;"><em><strong>Click here to download the brochure</strong></em></span></span></p>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/campionatore-attivo-per-il-campionamento-microbiologico-dellaria-microflow-alfa/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Microbiological air sampler  “Flow Impinger”</title>
		<link>https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-flow-impinger/</link>
		<comments>https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-flow-impinger/#comments</comments>
		<pubDate>Thu, 17 Dec 2015 09:45:07 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACTIVE SAMPLERS for MICROBIOLOGICAL air sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=845</guid>
		<description><![CDATA[The Flow Impinger has been developed for the sampling of bio-aerosol (e.g.: fungal spores, bacterial cells, etc) present in air. This type of sampling allows to verify and measure the presence of microorganism potentially harmful and identifying the source of pollution so as put to use a containment plan Sampling principle: The air is drawn through an external<p><a href="https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-flow-impinger/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p><i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="1" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/FlowImpinger.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/FlowImpinger.jpg" alt="FLOWIMPINGER" width="469" height="650" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/FlowImpinger.jpg" target="_self" >FLOWIMPINGER</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Flow-impinger_schema.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Flow-impinger_schema.jpg" alt="FLOWIMPINGER" width="388" height="500" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Flow-impinger_schema.jpg" target="_self" >FLOWIMPINGER</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Flow-impinger_schema.jpg" target="_self" >Scheme</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Componenti.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Componenti.jpg" alt="Components" width="517" height="600" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Componenti.jpg" target="_self" >Components</a></div>									</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Ugelli.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Ugelli.jpg" alt="Tangential nozzles" width="160" height="128" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Ugelli.jpg" target="_self" >Tangential nozzles</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div><br /></i><br />The <span style="color: #2a7ebc;"><strong><em>Flow Impinger</em></strong></span> has been developed for the sampling of bio-aerosol (e.g.: fungal spores, bacterial cells, etc) present in air. This type of sampling allows to verify and measure the presence of microorganism potentially harmful and identifying the source of pollution so as put to use a containment plan</p>
<p style="text-align: justify;"><strong><em><span style="color: #2a7ebc;">Sampling principle</span>:</em></strong> The air is drawn through an external sampler (e.g. CF20 Light) at constant speed for a variable time (depending on the nature of the environment to be monitored) through three nozzles, tangentially positioned inside the bubbler containing an appropriate liquid medium. The tangential movement of the particles inside the FlowImpinger, retains the particles in the collecting liquid. The suspension obtained, after homogenization and dilution, it&#8217;s sown directly in an agar ground. The use of a collecting liquid helps the dispersion of any airborne microbial aggregates, improves the cultivability of the microorganisms, allows the dilution of the sample in case of high contamination.</p>
<p style="text-align: justify;"><span id="more-845"></span></p>
<p style="text-align: justify;"><em><strong><span style="color: #2a7ebc;">Application fileds:</span></strong></em></p>
<ul style="list-style-type: square;">
<li style="text-align: justify;">security restricted areas</li>
<li style="text-align: justify;">hospitals</li>
<li style="text-align: justify;">pharmaceutical industries</li>
<li style="text-align: justify;">food and dairy company</li>
<li style="text-align: justify;">air treatment systems</li>
<li style="text-align: justify;">establishment for water purification sites</li>
<li style="text-align: justify;">working environments subject to controls as required by HACCP</li>
</ul>
<p style="text-align: justify;"> <br /><span style="color: #2a7ebc;"><em><strong>TECHNICAL FEATURES</strong></em></span></p>
<ul style="list-style-type: circle;">
<li style="text-align: justify;"><em>material:</em> glass sterilizable after use</li>
<li style="text-align: justify;"><em>composed by three parts:</em> input, the section with the three nozzles tangential and the collection bowl (20 ml).</li>
<li style="text-align: justify;"><em>liquid collecting:</em> water or other non-evaporable sterile liquids with viscosity up to 1000 times higher than water.</li>
<li style="text-align: justify;"><em>range of use:</em> 12,5 l/min</li>
<li style="text-align: justify;"><em>sampling efficiency:</em> about 100% for particles with size &gt; 1 micron<br />90% for particles with minor size (about 0,5 micron)</li>
<li style="text-align: justify;"><em>sampling time:</em> up to 8 hours</li>
<li style="text-align: justify;"><em>dimensions: </em>22 x 5 cm (h x diam.)</li>
<li style="text-align: justify;"><em>weight:</em> 158 gr</li>
</ul>
<p>&nbsp;</p>
<p><span style="color: #333399;"><strong>ACCESSORIES</strong></span></p>
<ul style="list-style-type: disc;">
<li style="text-align: justify;"><em><strong><span style="color: #2a7ebc;">Environmental</span><span style="color: #2a7ebc;"> sampling pump</span></strong></em>, mod. CF20 Light  (adjustable flow with flowmeter, with error ±5%, programmable or not)</li>
</ul>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-flow-impinger/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Portable sampler for compressed gas microbiological monitoring  “Microflow Compressed”</title>
		<link>https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-dei-gas-compressi-microflow-compressed/</link>
		<comments>https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-dei-gas-compressi-microflow-compressed/#comments</comments>
		<pubDate>Mon, 23 Feb 2015 14:02:45 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[ACTIVE SAMPLERS for MICROBIOLOGICAL air sampling]]></category>

		<guid isPermaLink="false">http://www.aquariasrl.com/h3o/?p=419</guid>
		<description><![CDATA[The Microflow Compressed has been specifically developed for bio-contaminant (eg: fungal spore, bacterial cells, etc.) sampling in compressed air or gas employed in manufacturing premises with controlled contamination areas. The aim of this sampling is to verify and quantify the presence of microorganism that may compromise the sterility of semifinished or finished products. For operating with “Microflow Compressed” is<p><a href="https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-dei-gas-compressi-microflow-compressed/" class="more-link themebutton">Read More</a></p>]]></description>
				<content:encoded><![CDATA[<p style="text-align: justify;"><i><div class="slideshow_container slideshow_container_style-light" style="height: 200px; " data-session-id="2" data-style-name="style-light" data-style-version="2.2.21">

			<div class="slideshow_loading_icon"></div>
	
	<div class="slideshow_content" style="display: none;">

		<div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_2.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_2.jpg" alt="MICROFLOW COMPRESSED" width="2272" height="1704" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_2.jpg" target="_self" >MICROFLOW COMPRESSED</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_2.jpg" target="_self" >Plate positioning site</a></div>				</div>
			</div>

			
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_3.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_3.jpg" alt="MICROFLOW COMPRESSED" width="2272" height="1704" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_3.jpg" target="_self" >MICROFLOW COMPRESSED</a></div>					<div class="slideshow_description"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/Campionatore-x-gas-compressi_3.jpg" target="_self" >Back view</a></div>				</div>
			</div>

			<div style="clear: both;"></div></div><div class="slideshow_view">
			<div class="slideshow_slide slideshow_slide_image">
				<a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_-flambatore.jpg" target="_self" >					<img src="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_-flambatore.jpg" alt="Pencil torch" width="581" height="386" />
				</a>				<div class="slideshow_description_box slideshow_transparent">
					<div class="slideshow_title"><a href="http://www.aquariasrl.com/en/wp-content/uploads/2016/02/MICROFLOW_-flambatore.jpg" target="_self" >Pencil torch</a></div>									</div>
			</div>

			<div style="clear: both;"></div></div>
	</div>

	<div class="slideshow_controlPanel slideshow_transparent" style="display: none;"><ul><li class="slideshow_togglePlay" data-play-text="Play" data-pause-text="Pause"></li></ul></div>

	<div class="slideshow_button slideshow_previous slideshow_transparent" role="button" data-previous-text="Previous" style="display: none;"></div>
	<div class="slideshow_button slideshow_next slideshow_transparent" role="button" data-next-text="Next" style="display: none;"></div>

	<div class="slideshow_pagination" style="display: none;" data-go-to-text="Go to slide"><div class="slideshow_pagination_center"></div></div>

	<!-- WordPress Slideshow Version 2.2.21 -->

	</div></i></p>
<p>The<span style="color: #2a7ebc;"><strong><em> Microflow Compressed</em></strong> </span>has been specifically developed for bio-contaminant (eg: fungal spore, bacterial cells, etc.) sampling in compressed air or gas employed in manufacturing premises with controlled contamination areas. The aim of this sampling is to verify and quantify the presence of microorganism that may compromise the sterility of semifinished or finished products.</p>
<p style="text-align: justify;">For<em><span style="color: #2a7ebc;"><strong> operating</strong></span></em> with “Microflow Compressed” is enough to connect the sampler to the area of interest through a sterile tube. Check with the pressure gauge that the pressure of the incoming gas is not higher than 4 bars (in this case it is necessary to reduce the pressure with a regulator placed upstream of the inlet tap) not to cause an excessive impact stress on the microorganisms. Through the flowmeter it is possible to adjust the air flow to the desired flow rate. The air, through the diffusion funnel, will impact on the plate with agar medium simply pushed by the gas pressure itself</p>
<p><span style="color: #2a7ebc;"><strong><em><br />Application fields</em></strong>:</span></p>
<ul style="list-style-type: square;">
<li style="text-align: justify;">security restricted areas</li>
<li style="text-align: justify;">hospital</li>
<li style="text-align: justify;">pharmaceutical industries</li>
<li style="text-align: justify;">food and dairy company</li>
<li style="text-align: justify;">air treatment systems</li>
<li style="text-align: justify;">water purification implants</li>
</ul>
<p style="text-align: justify;"> <br /><strong>The instrument is in </strong><strong><span style="color: #2a7ebc;">compliant</span> </strong><strong>with</strong><span style="color: #2a7ebc;"><span style="color: #000000;">:</span></span></p>
<p style="text-align: justify;">ISO 8573-1/4/7</p>
<p><strong><br /><em><span style="color: #2a7ebc;">TECHNICAL FEATURES</span></em></strong><span style="color: #2a7ebc;"><strong> </strong></span></p>
<ul style="text-align: justify; list-style-type: circle;">
<li><em>Anodised aluminium gas diffusive head with conical suction holes</em>i:<br /><strong><em>Head of 60</em></strong><em>:</em> 219 holes (ø 1 mm)<br /><strong><em>Head of 90:</em></strong> 380 holes (ø 1 mm)</li>
<li>Anodized aluminium plates support structure, autoclavable, with steel coupling springs</li>
<li>Bayonet head coupling system</li>
<li>Base and mounting bracket plate with blue epoxy powder coating</li>
<li>Air diffuser funnel in black PVC</li>
<li>Flowmeter range 50-400 litres</li>
<li>Manometer</li>
<li>Maximum compressed air input pressure: 4 bar</li>
<li>Operating temperature: 10 °C &#8211; 40 °C</li>
<li>Size: 400 x 210 x 250 mm (l x p x h)</li>
<li>Weight: ~ 4 Kg</li>
<li>Power supply: not required</li>
</ul>
<p><strong><em>If you need to record the sampling it is possible to use, in place of the housing of the plate, the sampler MicroFlow α.</em></strong><strong><em>The sampling time in this case will be governed by the same Microflow α.</em></strong></p>
<p>&nbsp;</p>
<p>The <span style="color: #2a7ebc;"><strong><em>kit may be required with</em></strong></span>:</p>
<ul style="text-align: justify;">
<li>sampling head of 60 for contact plates (Ø 60 ± 2 mm)</li>
<li>sampling head of 90 for Petri plates (Ø 90 ± 2 mm)</li>
<li>both the sampling group heads</li>
</ul>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;"><span style="color: #333399;"> <strong>ACCESSORIES</strong></span></p>
<ul>
<li style="text-align: justify;">
<p><strong><span style="color: #2a7ebc;">Pencil Torch</span> </strong>to sterilize the sampling head</p>
<p><span style="color: #2a7ebc;"><em><strong>Click here to download the brochure</strong></em></span></p>
</li>
</ul>
 ]]></content:encoded>
			<wfw:commentRss>https://www.aquariasrl.com/en/campionatore-per-il-campionamento-microbiologico-dei-gas-compressi-microflow-compressed/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
